TimeDomain CVD, Inc. |
|
|
What Determines the Wafer Temperature?In steady state, the amount of heat flowing into the wafer must equal the amount flowing out. Except at the wafer edges (an important place, to be sure!) the problem is essentially one-dimensional: the heat flows into the wafer from the heated wafer platen, and leaves to the gas and chamber ceiling. The situation is shown schematically below: The wafer is heated by conduction through an ambient or intentionally introduced backside gas such as helium. It can radiate to the ceiling and heat the ambient gas by convection and conduction. What are the heat fluxes?
Convection only at very high gas flows (many slpm for a 150 or 200 mm wafer) Conduction if the ceiling height is very small (<1 cm) and temperature moderate (<300 C) Radiation if the temperature is > 400 C or ceiling height is > 2 cm What temperature is the wafer at? This depends on the heat transfer to the wafer from the heater. A "flat" wafer on a "flat" platen will actually make contact with the platen in only a few isolated places; most of the heat is transferred either by radiation from the heater or by conduction through the gas. The spacing between the wafer and the platen can be assumed to be a few microns to a few 10's of microns for reasonably flat parts; this is less than the mean free path for LPCVD applications, so the heat transport is in the "accomodation" regime: that is, the atoms strike the wafer or heater surfaces much more than they strike each other. The amount of heat transported per unit area (MKS units!) is: Radiative transfer is the same as above: radiation between two planes. We need to adjust the wafer temperature until the heat flux in equals the heat flux out. Let's look at a practical example. For a gas flow of 300 sccm, chamber pressure of 1.5 Torr, ceiling height of 2 cm, reactor diameter (= wafer diameter) of 150 mm, accomodation coefficient of 0.25, and an aluminum heater (emissivity around 0.1) we find the heat balances:
That is, the wafer can be much cooler than the heater! Further, much of the transport is radiative, so changes in the chamber conditions (e.g. coating an initially reflective ceiling with a material such as silicon dioxide, which is fairly absorbtive in the infrared) will change the wafer temperature. The wafer temperature can also differ depending on the emissivity of the wafer, which depends on the doping, temperature, and what layers have been deposited on the wafer. So it is certainly not sufficient to accept the thermocouple measurement of the heater temperature as if it were the wafer temperature.
|